Inter-element phase self-calibration for GIMS (geostationary interferometric microwave sounder)
Bookreader Item Preview
Share or Embed This Item
Inter-element phase self-calibration for GIMS (geostationary interferometric microwave sounder)
- Publication date
- 2017-03
- Topics
- ChinaXiv, International Geoscience and Remote Sensing Symposium (IGARSS), 地球科学, 空间物理学, synthetic aperture, phase self-calibration, Geostationary Interferometric Microwave Sounder (GIMS), phase error
- Collection
- chinaxivmirror; journals
- Rights
- https://chinaxiv.org/user/license.htm
- Item Size
- 5.5M
Inter-element phase self-calibration for GIMS (geostationary interferometric microwave sounder)
- 作者: Han, Donghao 1,2 Liu, Hao 1 Wu, Ji 1 Zhang, Cheng 1
- 作者单位:
- 提交时间: 2017-03-10
摘要: The inter-element phase calibration plays an important role in the overall calibration scheme for synthetic aperture radiometer. The traditional relative phase calibration approach is to use correlated noise injection network, which will be difficult to be implemented in millimeter wave band due to the complexity of the waveguide divider network. A novel self-calibration method for interferometric radiometers with rotating thinned array, especially for the geostationary interferometric microwave sounder(GIMS), has been proposed in this paper. By using this approach, neither dedicated hardware nor dedicated calibration working model is needed to achieved the relative phase calibration. The self-calibration approach is inherently merged with the nominal observation working model of GIMS, thanks to the continuous array rotating of GIMS instrument. A running average scheme has been introduced into the self-calibration approach to enhance the SNR of the calibration data, which is normally very low with the natural earth scene. The method is demonstrated by both simulation and field imaging experiment. �2016 IEEE.
- 期刊: International Geoscience and Remote Sensing Symposium (IGARSS)
- 分类: 地球科学 >> 空间物理学
-
引用:
ChinaXiv:201703.00288
(或此版本
ChinaXiv:201703.00288V1
)
doi:10.12074/201703.00288
CSTR:32003.36.ChinaXiv.201703.00288.V1 - 推荐引用方式: Han, Donghao,Liu, Hao,Wu, Ji,Zhang, Cheng.(2017).Inter-element phase self-calibration for GIMS (geostationary interferometric microwave sounder).International Geoscience and Remote Sensing Symposium (IGARSS).[ChinaXiv:201703.00288]
版本历史
| [V1] | 2017-03-10 11:31:19 | ChinaXiv:201703.00288V1 | 下载全文 |
Notes
- 元数据由脚本提取,仅供参考,以 ChinaXiv.org 官网为准。(如元数据识别有误/需要更新,请留言)
- 截至 2023-11-28,ChinaXiv 背后的 istic.ac.cn 维护的 DOI 前缀 https://doi.org/10.12074 大量新论文的 DOI 链接无法正确重定向,因此使用者请谨慎使用 external-identifier 中的 DOI 链接。(使用前看下 DOI 跳转是否正常。如正常,则永久有效)
- 部分论文并没有使用 DOI 10.12074 前缀(例如 https://chinaxiv.org/abs/202205.00023 ),它们的元数据可能异常。
- “版本历史”的“下载全文”按钮链接到的是 ChinaXiv.org 的原始链接,未来可能会失效。
- Addeddate
- 2023-12-10 13:42:59
- Chinaxiv
- 201703.00288
- Chinaxiv_copyquotation
- Han, Donghao,Liu, Hao,Wu, Ji,Zhang, Cheng.(2017).Inter-element phase self-calibration for GIMS (geostationary interferometric microwave sounder).International Geoscience and Remote Sensing Symposium (IGARSS).[ChinaXiv:201703.00288]
- Chinaxiv_id
- 6581
- External-identifier
-
urn:chinaxiv:201703.00288
urn:chinaxiv:201703.00288V1
urn:doi:10.12074/201703.00288
urn:cstr:32003.36.ChinaXiv.201703.00288.V1 - Identifier
- ChinaXiv-201703.00288V1
- Identifier-ark
- ark:/13960/s2hnjj8r9ms
- Journal
- International Geoscience and Remote Sensing Symposium (IGARSS)
- Ocr
- tesseract 5.3.0-6-g76ae
- Ocr_autonomous
- true
- Ocr_detected_lang
- en
- Ocr_detected_lang_conf
- 1.0000
- Ocr_detected_script
- Latin
- Ocr_detected_script_conf
- 1.0000
- Ocr_module_version
- 0.0.21
- Ocr_parameters
- -l eng+Latin
- Page_number_confidence
- 0
- Page_number_module_version
- 1.0.3
- Ppi
- 300
- Scanner
- ChinaXivXiv v0.1.0
- Source
-
https://chinaxiv.org/abs/201703.00288v1
comment
Reviews
55 Views
DOWNLOAD OPTIONS
For users with print-disabilities
IN COLLECTIONS
ChinaXIV Mirror ProjectUploaded by chinaxiv_mirror on
Open Library